UAC Registrant Module

Edited by

Ovidiu Sas

Revision History
Revision $Revision$$Date: 2011-06-30 16:23:37 +0200 (Thu, 30 Jun 2011) $

Table of Contents

1. Admin Guide
1.1. Overview
1.2. Dependencies
1.2.1. OpenSIPS Modules
1.2.2. External Libraries or Applications
1.3. Exported Parameters
1.3.1. hash_size (integer)
1.3.2. timer_interval (integer)
1.3.3. db_url (string)
1.3.4. table_name (string)
1.3.5. registrar_column (string)
1.3.6. proxy_column (string)
1.3.7. aor_column (string)
1.3.8. third_party_registrant_column (string)
1.3.9. username_column (string)
1.3.10. password_column (string)
1.3.11. binding_URI_column (string)
1.3.12. binding_params_column (string)
1.3.13. expiry_column (string)
1.3.14. forced_socket_column (string)
1.4. Exported Functions
1.5. Exported MI Functions
1.5.1. reg_list

List of Examples

1.1. Set hash_size parameter
1.2. Set timer_interval parameter
1.3. Set “db_url” parameter
1.4. Set “table_name” parameter
1.5. Set “registrar_column” parameter
1.6. Set “proxy_column” parameter
1.7. Set “aor_column” parameter
1.8. Set “third_party_registrant_column” parameter
1.9. Set “username_column” parameter
1.10. Set “password_column” parameter
1.11. Set “binding_URI_column” parameter
1.12. Set “binding_params_column” parameter
1.13. Set “expiry_column” parameter
1.14. Set “forced_socket_column” parameter

Chapter 1. Admin Guide

1.1. Overview

The module enable OpenSIPS to register itself on a remote SIP registrar. Several registrant accounts can be defined, each account is specified by the "uac" parameter.

At startup, the registrant records are loaded into a hash table in memory and a timer is started. The hash index is computed over the AOR field. For better hash distribution, the size of the hash table is configurable. When the timer fires for the first time, the first hash table will be checked and REGISTERs will be sent out for each record that is found. On the next timeout fire, the second hash table will be checked and so on. The timer interval is configurable.

Each registrant has it's own state. Registranr's status can be inspected via "reg_list" MI comand.

UAC registrant states:

  • 0 - NOT_REGISTERED_STATE - the initial state (no REGISTER has been sent out yet);

  • 1 - REGISTERING_STATE - waiting for a reply from the registrar after a REGISTER without authentication header was sent;

  • 2 - AUTHENTICATING_STATE - waiting for a reply from the registrar after a REGISTER with authentication header was sent;

  • 3 - REGISTERED_STATE - the uac is successfully registered;

  • 4 - REGISTER_TIMEOUT_STATE : no reply received from the registrar;

  • 5 - INTERNAL_ERROR_STATE - some errors were found/encountered during the processing of a reply;

  • 6 - WRONG_CREDENTIALS_STATE - credentials rejected by the registrar;

  • 7 - REGISTRAR_ERROR_STATE - error reply received from the registrar;

1.2. Dependencies

1.2.1. OpenSIPS Modules

The following modules must be loaded before this module:

  • uac_auth - UAC authentication module

1.2.2. External Libraries or Applications

None.

1.3. Exported Parameters

1.3.1. hash_size (integer)

The size of the hash table internally used to keep the registrants. A larger table distributes better the registration load in time but consumes more memory. The hash size is a power of number two.

Default value is 1.

Example 1.1. Set hash_size parameter

...
modparam("uac_registrant", "hash_size", 2)
...

1.3.2. timer_interval (integer)

Defines the periodic timer for checking the registrations status.

Default value is 100.

Example 1.2. Set timer_interval parameter

...
modparam("uac_registrant", "timer_interval", 120)
...

1.3.3. db_url (string)

Database where to load the registrants from.

Default value is “NULL” (use default DB URL from core).

Example 1.3. Set “db_url” parameter

...
modparam("uac_registrant", "db_url", "mysql://user:passw@localhost/database")
...

1.3.4. table_name (string)

The database table that holds the registrant records.

Default value is “registrant”.

Example 1.4. Set “table_name” parameter

...
modparam("uac_registrant", "table_name", "my_registrant")
...

1.3.5. registrar_column (string)

The column's name in the database storing the URI pointing to the remote registrar (mandatory field). OpenSIPS expects a valid URI.

Default value is “registrar”.

Example 1.5. Set “registrar_column” parameter

...
modparam("uac_registrant", "registrar_column", "registranr_uri")
...

1.3.6. proxy_column (string)

The column's name in the database storing the URI pointing to the outbond proxy (not mandatory field). An empty or NULL value means no outbound proxy, otherwise OpenSIPS expects a valid URI.

Default value is “proxy”.

Example 1.6. Set “proxy_column” parameter

...
modparam("uac_registrant", "proxy_column", "proxy_uri")
...

1.3.7. aor_column (string)

The column's name in the database storing the URI defining the address of record (mandatory field). The URI stored here will be used in the To URI of the REGISTER. OpenSIPS expects a valid URI.

Default value is “aor”.

Example 1.7. Set “aor_column” parameter

...
modparam("uac_registrant", "aor_column", "to_uri")
...

1.3.8. third_party_registrant_column (string)

The column's name in the database storing the URI defining the third party registrant (not mandatory field). The URI stored here will be used in the From URI of the REGISTER. An empty or NULL value means no third party registration (the From URI will be identical to To URI), otherwise OpenSIPS expects a valid URI.

Default value is “third_party_registrant”.

Example 1.8. Set “third_party_registrant_column” parameter

...
modparam("uac_registrant", "third_party_registrant_column", "from_uri")
...

1.3.9. username_column (string)

The column's name in the database storing the username for authentication (mandatory if the registrar requires authentication).

Default value is “username”.

Example 1.9. Set “username_column” parameter

...
modparam("uac_registrant", "username_column", "auth_username")
...

1.3.10. password_column (string)

The column's name in the database storing the password for authentication (mandatory if the registrar requires authntication).

Default value is “password”.

Example 1.10. Set “password_column” parameter

...
modparam("uac_registrant", "password_column", "auth_passowrd")
...

1.3.11. binding_URI_column (string)

The column's name in the database storing the binding URI in REGISTER (mandatory field). The URI stored here will be used in the Contact URI of the REGISTER. OpenSIPS expects a valid URI.

Default value is “binding_URI”.

Example 1.11. Set “binding_URI_column” parameter

...
modparam("uac_registrant", "binding_URI_column", "contact_uri")
...

1.3.12. binding_params_column (string)

The column's name in the database storing the binding params in REGISTER (not mandatory field). If not NULL or not empty, the string stored here will be added as paramns to the Contact URI in REGISTER (it MUST start with “;”. There is no validation on the string stored here.

Default value is “binding_params”.

Example 1.12. Set “binding_params_column” parameter

...
modparam("uac_registrant", "binding_params_column", "contact_params")
...

1.3.13. expiry_column (string)

The column's name in the database storing the expiration time (not mandatory).

Default value is “expiry”.

Example 1.13. Set “expiry_column” parameter

...
modparam("uac_registrant", "expiry_column", "registration_timeout")
...

1.3.14. forced_socket_column (string)

The column's name in the database storing the socket for sending the REGISTER (not mandatory). If a forced socket is provided, the socket MUST be explicitely set as a global listening socket in the config (see “listen” core parameter).

Default value is “forced_socket”.

Example 1.14. Set “forced_socket_column” parameter

...
modparam("uac_registrant", "forced_socket_column", "fs")
...

1.4. Exported Functions

None to be used in configuration file.

1.5. Exported MI Functions

1.5.1. reg_list

Lists the registrant records and their status.

Name: reg_list

Parameters: none

MI FIFO Command Format:

:reg_list:_reply_fifo_file_
_empty_line_